Startseite
ÜBER UNS TECHNIK EINSPARUNG VERLEGEPLÄNE BILDERGALERIE


Technology
 
Flow temperature
40°C
45°C
50°C
55°C
60°C
65°C
70°C
75°
80°C
85°C
Output per meter
88 W
105 W
132 W
149 W
178 W
197 W
226 W
246 W
277 W
294 W

Average Input (flow) temperature
40 - 50
°C
Temperature difference between flow and return
5
°C
Volume of water per linear meter flow and return
0,34
Litre
Maximum length of single circuit
12,5
Meters
Outside diameter of PO - XC pipe (VR)
13
mm
Inside diameter of PO PE - XC pipe (VR)
10
mm
Diameter of protective sheath
20
mm
Temperature resistance of PO - XC pipe
minus 50°C
plus 130°C

Total installation rating
v. 5-10
KW
 
v. 10-22
KW
 
v. 22-25
KW
 
v. 25-30
KW
Diameter of main feed pipe
18 mm
 
22 mm
 
28 mm
 
35 mm

Number of circuits
2
3
4
5
6
7
8
9
10
Manifold length (VT)
200
mm
260
mm
310
mm
370
mm
420
mm
470
mm
530
mm
590
mm
650
mm
Height of manifold
320 mm
Depth of manifold
80 mm

Finished floor level to upper edge of manifold box
700
mm
Depth of manifold box
120
mm
Width of manifold box
Manifold + 250 mm
mm

Thermostat dimensions (TH)
Width
75 mm
Heigth
77 mm
Depth
26 mm

Transformer dimensions (NT)
Width
107 mm
Heigth
125 mm
Depth
61 mm

Skirting-board dimensions
Width
2.500 mm
Heigth
137 mm
Depth
28 mm

KONTAKT